导航:Home > 配件耗材 >

热机械分析仪 部件及附件 RSA-G2 & DMA 850 TAinstruments

备件

备件

P/N: Product Description
203330.001 Keysight E4980AL-102 LCR MeterNote: For ARES-G2, RSA-G2, and DHR DETA: frequency range: 20Hz to 1MHz; AC test signal (potential) 0.001 to 2 Volts (115/230VAC; 50/60Hz).
203599.901 Universal AC adapter kit for DSL Router
251471.002 DSL Router with 4-Port SwitchNote: For communication between an external controller and Thermal and Rheology instruments.
251471.002 DSL Router with 4-Port Switch
259508.000 Brass Tweezers
270962.002 Telescoping GaugeNote: For 17 mm single cantilever clamps.
270975.001 Filter Replacement, Auto Drain Regulator
270976.002 Filter/Regulator with Auto Drain
401041.901 ARES-G2, RSA-G2 and DMA 3200 FCO LN2 Controller Option
401711.901 ARES-G2 and RSA-G2 FCO Camera
401798.901 ARES/RSA3 to ARES-G2/RSA-G2 LN2 Upgrade Kit
401892.901 RSA-G2 Forced Convection Oven FCO
402198.901 RSA Immersion Geometry and Installation KitNote: Includes Tension and 15 mm diameter Compression Fixtures.Also includes 10 mm, 15 mm, and 20 mm 3-point bending fixtures.Compatible with the RSA-G2.
402551.901 ARES-G2 and RSA-G2 DETA Accessory Kit (LCR Meter not included)Note: Requires two RSA-G2 25 mm DETA Geometries (P/N: 402614.901)and customer-supplied Keysight E4980A LCR Meter (P/N: 613.04946), orKeysight E4980AL LCR Meter (P/N: 203330.001).
402614.901 RSA-G2 25 mm DETA GeometryNote: For use with the RSA-G2 DETA option (P/N: 402551.901).
404005.901 RSA-G2, Disposable DETA GeometryNote: For use with the RSA-G2 DETA option (P/N: 402551.901).
404041.901 ARES-G2, RSA-G2, & DMA 3200 FCO Air Chiller PanelNote: For use with ACS-2 and ACS-3 Air Chiller Systems.
405000.901 ACS-3 Air Chiller System (240VAC; 60Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel(P/N: 404041.901) for operation.
405000.901 ACS-3 Air Chiller System (240VAC; 60Hz)Note: Requires DMA 850 & Q800 Air Chiller Panel (P/N: 986400.901) foroperation.
405000.902 ACS-3 Air Chiller System (220-230VAC/50Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel(P/N: 404041.901) for operation.
405000.902 ACS-3 Air Chiller System (220-230VAC; 50Hz)Note: Requires DMA 850 & Q800 Air Chiller Panel (P/N: 986400.901) foroperation.
405001.901 ACS-2 Air Chiller System (240VAC; 60Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel(P/N: 404041.901) for operation.
405001.901 ACS-2 Air Chiller System (240VAC; 60Hz)Note: Requires DMA 850 & Q800 Air Chiller Panel (P/N: 986400.901) foroperation.
405001.902 ACS-2 Air Chiller System (220-230VAC; 50Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel(P/N: 404041.901) for operation.
405001.902 ACS-2 Air Chiller System (220-230VAC; 50Hz)Note: Requires DMA 850 & Q800 Air Chiller Panel (P/N: 986400.901) foroperation.
613.04946 Keysight E4980A LCR MeterNote: For ARES-G2 and RSA-G2 DETA: frequency range: 20Hz. to 2MHz.; AC test signal (potential) 0.005 to 20 Volts (115/230VAC; 50/60Hz).
700.02657.2 ARES, RSA, and TAM Air Dryer
708.01446 RSA-G2 and DMA 3200 Cantilever Bending Geometry
708.01455 RSA-G2 and DMA 3200 Film / Fiber Geometry
708.01456 RSA-G2 and DMA 3200 3-Point Bending Geometry
708.01461 RSA-G2 and DMA 3200 Shear Sandwich Geometry
708.01464 RSA-G2 and DMA 3200 Parallel Plate Compression Geometry
708.01465 RSA-G2 Contact Lens Geometry Probe and Lens Holder
708.01466.1 Replacement 8 mm diameter PlatesNote: For RSA-G2 and DMA 3200 Compression Geometry.
708.01466.2 Replacement 15 mm diameter PlatesNote: For RSA-G2 and DMA 3200 Compression Geometry.
708.01466.3 Replacement 25 mm diameter PlatesNote: For RSA-G2 and DMA 3200 Compression Geometry.
900902.901 Indium Temperature Calibration Sample
900907.901 Zinc Temperature Calibration Sample
980228.902 Glass Support Cloth (0.2 mm thick, 33 m length)
982161.902 ABS Sample (3.18 mm thick, 61 mm length) (pkg. of 5)
982161.903 ABS Sample (3.18 mm thick, 36 mm length) (pkg. of 5)
982165.902 Polycarbonate Sample (1.6 mm thick, 60 mm length) (pkg. of 5)
982165.903 Polycarbonate Sample (1.6 mm thick, 36 mm length) (pkg. of 5)
982165.904 Polycarbonate Sample (0.79 mm thick, 36 mm length) (pkg. of 5)
982166.003 Compliance Sample – Dual Cantilever
982166.004 Compliance Sample – Single Cantilever
984014.901 3-Point Bending Kit (20 and 50 mm) for DMA 850 & Q800
984015.901 35 mm Single / Dual Cantilever Kit for DMA 850 & Q800
984017.901 Shear Sandwich Clamp Kit
984022.901 Penetration Clamp Kit
984023.901 Specialty Fiber Tension Clamp Kit
984026.901 3-point Bending Clamp Kit (5, 10, and 15 mm lengths)
984047.901 20 mm Single/Dual Cantilever Clamp Kit
984048.901 8 mm Single/Dual Cantilever Clamp Kit
984308.001 DMA Calibration Standard 0.005 inch thick
984308.002 DMA Calibration Standard 0.010 inch thick
984308.003 DMA Calibration Standard 0.020 inch thick
984308.004 DMA Calibration Standard 0.030 inch thick
984309.901 Polyethylene Terephthalate (PET) Film (38 mm length) (pkg. of 10)
984310.901 Indium Wire, Film/Fiber Temperature Calibration (38 mm length)(pkg. of 10)
984313.901 PET Fiber (910 mm length)
984331.901 Film/Fiber Tension Clamp Calibration Kit
984370.901 Furnace Inlet Ferrule/Spring Kit (pkg. of 5)
984486.901 Film Cutting Kit
985011.901 Accessory Kit, Q800 DMA (supplied with the Q800 DMA module)
985016.901 Film/Fiber Tension Kit DMA 850 / Q800 (Single Screw Design, Mk II)
985018.901 DMA-RH Accessory Clamp Kit for DMA 850 & Q800Note: Specifically for use with the DMA-RH Accessory. Includes clamp components for 10 mm 3-pt bending, penetration, and 15 mm compression clamps.
985052.901 Thermocouple Baffle
985069.901 3-point Bending Clamp Kit (50 mm, low friction)
985070.901 3-point Bending Clamp Kit (20 mm, low friction)
985078.001 Dual Cantilever Clamp Screen
985078.002 Film/Fiber Tension Clamp Screen
985098.901 Q800 Submersion Clamp ThermocoupleNote: Required for customers who intend to use a DMA 850 submersionclamp kit with their Q800. Requires service engineer installation (quotedseparately).
985164.901 Powder KitNote: For use with 35 mm Cantilever Clamp Kit (P/N: 984015.901).
985700.901 DMA-RH (Relative Humidity) Accessory for DMA 850 & Q800
986012.901 Discovery DMA 850 Standard Furnace
986018.901 Accessory Kit, DMA 850 (supplied with the DMA 850 module)
986252.901 Film/Fiber Tension Kit DMA 850 / Q800 (Dual Screw Design, Mk III)
986260.901 Submersion Compression Clamp Kit for DMA 850
986261.901 Submersion Film / Fiber Tension Kit for DMA 850
986262.901 Submersion 3-Point Bending Clamp Kit for DMA 850
986270.901 Parallel Plate Compression Kit for DMA 850 & Q800
986310.901 Nitrogen Purge Cooler
986320.901 DMA 850 Filter/Regulator
986325.901 DMA 850 Submersion Clamp ThermocoupleNote: Required for customers who intend to use an existing Q800submersion clamp kit with their new DMA 850. Requires service engineerinstallation (quoted separately).
986345.901 DMA-RH DMA 850 Adapter
986350.901 Air Compressor Accessory (ACA) for DMA 850
986400.901 DMA 850/Q800 DMA Air Chiller PanelNote: For use with ACS-2 and ACS-3 Air Chiller Systems.
991600.901 Gas Cooling Accessory – Auto Tank Fill (for cooling to -150 °C)