part number | description | ||
910-00051 | Nano spray tip 360/20 μm ID/OD; 10 μm tip; 5/pkg | ||
910-00052 | Nano spray tip 360/20 μm ID/OD; 10 μm tip; 20/pkg | ||
800-00448 | 50 µm ID union with adapter for Proxeon Nanospray Source | ||
800-00422 | 50 µm ID union for New Objective nanospray source; includes 5 New Objective nanospray tips | ||
910-00112 | 50 µm ID union with adapter for AB SCIEX Nanospray III; includes 5 New Objective nanospray tips | ||
200-00407 | 50 µm ID replacement union for nanospray | ||
200-00408 | Valco Nut/Ferrule,PEEK, for 360 µm fused silica tubing | ||
accessories and consumables – nanoLC-Ultra | |||
part number | description | ||
800-00208 | Peptide standard (5 peptides; 1 mg each) | ||
801-00093 | accessory kit nanoLC Ultra | ||
801-00063 | Flow rate calibration kit nanoLC-Ultra for 1 – 30 µL/min flow rate | ||
801-00064 | Flow rate calibration kit nanoLC-Ultra for 50 – 1000 nl/min flow rate | ||
200-00339 | 1/32″ plug | ||
910-00085 | 1/32″ nut (long) 10/pkg | ||
910-00086 | 1/32″ nut (short) 10/pkg | ||
910-00087 | 1/32″ ferule 10/pkg | ||
910-00088 | 1/32″ sleeve for 365 μm OD fused silica capillary 10/pkg | ||
200-00301 | 1/32″ SS union with short nuts and ferules | ||
200-00319 | 1/32 Microtight union (includes fittings) | ||
910-00089 | 1/32 Microtight fitting 10/pkg | ||
205-00048 | 20 μm ID /1/32″ OD x 75 cm PEEKSil tubing (black) | ||
205-00052 | 20 μm ID /1/32″ OD x 15 cm PEEKSil tubing (black) | ||
205-00049 | 50 μm ID /1/32″ OD x 75 cm PEEKSil tubing (natural) | ||
200-00329 | Mobile Phase filter | ||
910-00090 | 1/8 ” Super Flangeless nut 10/pkg | ||
910-00091 | 1/8 ” Super Flangeless ferule10/pkg | ||
accessories and consumables – nanoLC-Ultra AS-2 autosampler | |||
part number | description | ||
200-00334 | rotor for 1/32″ 6 port injection valve (10,000 psi) | ||
620-00149 | Tubing set 1/32″ Valco, AS-2 (0845.332) | ||
801-00090 | PM Kit AS-2, Includes needle, syringe and rotor | ||
620-00064 | Syringe 25 μl for AS-1 and AS-2 | ||
5016574 | Syringe 50 μl for AS-2 | ||
910-00081 | PEEKsil sample loop 1 μl, 1/32″ OD | ||
910-00108 | PEEKsil sample loop 5 μl, 1/32″ OD | ||
910-00082 | PEEKsil sample loop 10 μl, 1/32″ OD | ||
910-00083 | PEEKsil sample loop 20 μl, 1/32″ OD | ||
5016578 | 10 μl SS loop, 1/32” | ||
5016279 | 20 μl SS ,loop 1/32” | ||
620-00147 | air needle 62 mm | ||
620-00196 | air needle 80 mm | ||
620-00148 | sample needle 2.4 μl | ||
5016577 | Union for AS2 needle (2.4 μl) 150 μm ID | ||
5016575 | sample needle 15 μl (0.25 mm ID side-port) for AS-2 | ||
5016576 | Union for AS2 needle (15 μl) 0.25 mm ID | ||
620-00152 | 12 vial adapter | ||
620-00153 | 48 vial adapter | ||
910-00104 | 11 mm PP 250 µl vial (100/pkg) | ||
910-00103 | 11 mm snap cap with slit septum (100/pkg) | ||
910-00096 | 11 mm PP 250 µl vial + snap cap with slit septum (20/pkg) | ||
accessories and consumables – nanoLC | |||
part number | description | ||
930-00026 | 1 port USB to serial converter | ||
930-00028 | 2 port USB to serial converter | ||
800-00039 | Injection valve mounting kit for use with CTC PAL autosampler. Includes valve mounting bracket and injection port assembly. Does not include injection valve; please order injection valve separately, or order NanoLC system with injection valve. Mounting of CTC on top of 2D pump requires 2D chassis modifications and additional brackets. |
||
800-00454 | Injection valve mounting kit for use with CTC PAL autosampler. Includes 1/32″ 10,000 psi injection valve, mounting bracket and injection port assembly. |
||
200-00159 | Replacement rotor for Titanium 10-port valve | ||
200-00211 | Replacement rotor for PAEK 10-port valve | ||
800-00006 | Accessories kit for 1D. Includes calibration kit, syringe, fittings, capillary tubing and cables. | ||
801-00001 | Accessories kit for 1Dplus and 2D. Includes mobile phase reservoirs, calibration kits, priming tool and syringe, fittings, capillary tubing and cables. |
||
801-00002 | Flow rate calibration kit with 20 μl calibrated pipettes (10) for 1 – 30 μl/min flow rate | ||
801-00020 | Replacement calibration pipettes, 20 μl, for 1-30 μl/min, 10/pkg | ||
801-00006 | Flow rate calibration kit with 5 μl calibration pipettes (5) for 50 – 1000 nl/min flow rate | ||
910-00006 | Obsolete. Replaced by p/n 801-00006 | ||
910-00007 | Replacement calibration pipettes, 5 μl, for 50 – 1000 nl/min, 10/pkg | ||
801-00003 | Pump priming tool kit, includes 10 ml syringe | ||
200-00033 | 10 ml syringe | ||
200-00096 | Fused Silica Cutter | ||
910-00020 | Fitting, FingerTight, 1/16″, PEEK, 10/pkg | ||
910-00021 | Fitting, hex, 1/16″, SS, 0.43″ long, 10/pkg | ||
920-00006 | PEEK hex nut, 10/pkg | ||
910-00023 | Ferrule, 1/16″, PEEK, 10/pkg | ||
910-00026 | Ferrule, 1/16″, SS, 10/pkg (200-00018) | ||
920-00004 | Fitting, hex, 1/16″, SS, 3/4″ long, 10/pkg | ||
920-00005 | Fitting, hex, 1/16″, PEEK, 3/4″ long, 10/pkg | ||
920-00008 | Sleeve, FEP, green, 395 μm ID, 1/16″ OD, 10/pkg | ||
910-00022 | Fitting, MicroTight, 0.025″, PEEK, 10/pkg | ||
920-00002 | Ferrule, MicroTight, for 0.025″, 10/pkg | ||
200-00089 | 10-32 LiteTouch fitting for 1/16″ OD tubing | ||
200-00002 | MicroTight union, PEEK (for connection of flow modules) | ||
200-00037 | MicroTight adapter union 10-32 1/16″ to 6-32 for 0.025″ sleeves | ||
200-00072 | MicroTight True ZDV union for 0.025″ MicroTight Sleeves, PEEK | ||
200-00044 | Plug, MicroTight, PEEK, black | ||
920-00003 | Nut, female, MicroTight, 10/pkg | ||
910-00043 | Sleeve, PEEK, yellow, 180 μm ID, 0.025″ OD, 10/pkg | ||
910-00024 | Sleeve, PEEK, orange, 405 μm ID, 1/16″ OD, 10/pkg | ||
910-00025 | Sleeve, PEEK, green, 395 μm ID, 0.025″ OD, 10/pkg | ||
200-00138 | Mixing tee ferrule for 365 μm OD capillary, 1/pkg | ||
910-00002 | Capillary tubing, 360 μm OD, 50 μm ID, 2 m | ||
910-00008 | Capillary tubing, 360 μm OD, 25 μm ID, 2 m | ||
910-00109 | Capillary tubing, 360 μm OD, 75 μm ID, 2 m | ||
910-00046 | Capillary tubing, 360 μm OD, 100 μm ID, 2 m | ||
accessories and consumables – nanoLC AS-1 autosampler | |||
part number | description | ||
620-00165 | Adapter for micro-titerplates | ||
801-00007 | Conversion kit NanoLC autosampler for large volume injections. Includes 100 μl syringe, 5.4 μl fused silica needle, 500 μl buffer tubing and 50 μl PEEK loop |
||
801-00037 | Re-installation Kit for AS-1 with titanium valve. Includes Eksigent Firmware (620-00034), valve stator (200-00131), rotor (200-00160), syringe (620-00064), pre-puncture needle (620-00021), sample needle (800-00044), buffer tubing (800-00064), 10 µl sample loop (620- 00039), P1-output (800-00060) and P6-input (800-00059) cables. |
||
801-00038 | Re-installation Kit for PAEK AS-1 with PAEK valve. Includes Eksigent Firmware (620-00034), valve stator (200-00048), rotor (200-00057), syringe (620-00064), pre-puncture needle (620-00021), sample needle (800-00044), buffer tubing (800-00064), 10 µl sample loop (620- 00039), P1-output (800-00060) and P6-input (800-00059) cables. |
||
200-00160 | Replacement rotor for Titanium 6-port valve | ||
200-00047 | Replacement rotor for 6 port PEAK injection valve (0.25 mm) | ||
620-00021 | Air/pre-puncturing needle | ||
800-00044 | Fused silica needle 2.4 μl Bio | ||
620-00139 | Peeksil needle 2.4 μl | ||
800-00045 | Fused silica needle 5.4 μl Bio | ||
200-00061 | PEEK sample loop, 2 μl, 1/16″ OD | ||
200-00092 | PEEK sample loop, 5 μl, 1/16″ OD | ||
200-00164 | PEEK sample loop, 10 μl, 1/16″ OD | ||
200-00093 | PEEK sample loop, 20 μl, 1/16″ OD | ||
200-00063 | PEEK sample loop, 50 μl, 1/16″ OD | ||
200-00208 | PEEKSil sample loop, 1 μl, 1/16″ OD | ||
620-00039 | PEEKSil sample loop, 10 μl, 1/16″ OD | ||
620-00064 | Syringe 25 μl for AS-1 and AS-2 | ||
620-00140 | Teflon seal between syringe and syringe valve | ||
910-00045 | Replacement tip for 25 μl syringe, 5/pkg | ||
620-00065 | Syringe 100 μl | ||
910-00077 | 10 ml reagent vial 10/pkg | ||
800-00063 | Buffer tubing, 500 μl | ||
800-00064 | Buffer tubing, 50 μl | ||
accessories and consumables – cHiPLC nanoflex | |||
part number | description | ||
800-00408 | Direct injection jumper chip | ||
800-00389 | Trap-elute jumper chip | ||
800-00421 | Dual column jumper chip | ||
800-00447 | Nanoflex shelf | ||
801-00078 | Accessory Kit, cHiPLC-Nanoflex | ||
700-00063 | External Cable, Nanoflex to Ultra Nano | ||
700-00064 | External Cable, Nanoflex to NanoLC (legacy) | ||
200-00386 | Filter holder between pump and autosampler | ||
910-00098 | Filter element for filter between pump and autosampler (10/pkg) | ||
200-00381 | replacement union Nanoflex to Nanospray source | ||
910-00097 | Fitting for valve nanoflex (10/pkg) | ||
910-00111 | 1/32″ PEEK nut and ferrule for Nanoflex C2N valve (10 pack) | ||
910-00099 | No longer available; replaced with p/n 910-00110 | ||
910-00110 | 1/32″ OD sleeve for 180 µm OD tubing (200-00422; 10/pkg) | ||
910-00100 | 0.025″ OD sleeve for 180µm OD tubing (910-00043; 10/pkg) | ||
200-00427 | rotor for Nanoflex C2N valve | ||
100-00593 | Hex key driver for nanoflex | ||
accessories and consumables – ekspot MALDI spotter | |||
part number | description | ||
620-00135 | Obsolete, replaced with p/n 620-00134 | ||
620-00143 | Two drawer stack. Holds four microtiterplate format MALDI targets or microtiterplates (standard or deep well) | ||
620-00146 | Cooled two drawer stack. Holds four microtiterplate format MALDI targets or microtiterplates (standard or deep well) | ||
620-00138 | Four drawer stack. Holds 8 microtiterplate format MALDI targets. | ||
910-00061 | 50 µl syringe | ||
200-00273 | 100 µl syringe | ||
200-00274 | 250 µl syringe | ||
801-00050 | Accessory kit ekspot. Includes spotting tips, support needles, fittings and tubing | ||
801-00052 | Spotting tip 25 μm i.d. /360 μm o.d. | ||
200-00265 | Steel support needle | ||
200-00271 | FEP Dual Sleeve for Upchurch Y-connector | ||
200-00008 | FEP Sleeve | ||
200-00266 | Upchurch Y-connector | ||
200-00259 | Frit with Ferrule for Y-connector | ||
200-00270 | Ferrule for Y-connector | ||
800-00071 | Matrix bottle (4 ml) | ||
801-00051 | Waste vial (20 ml) with septum | ||
611-00043 | User manual for ekspot MALDI spotter | ||
computer, instrument cart and compressor | |||
part number | description | ||
930-00019 | Mini-tower PC for Express 800 (Windows XP Professional) | ||
900-00027 | Instrument cart | ||
930-00021 | Air compressor, without refrigerated water trap | ||
930-00022 | Air compressor dryer kit | ||
930-00023 | Air compressor, includes refrigerated water trap | ||
ESI probes and electrodes for use with MicroLC systems | |||
part number | description | ||
801-00084 | ABSCIEX Interface kit for ExpressHT-Ultra; includes 25 µm ID electrode (5016874) and 50 µm ID electrode (5016411), column oven clamp (5015996), grounding kit (5016941) and MS interface cable (700-00049) NOTE: Does NOT include Turbo V probe housing (ABSCIEX PN 1017167) |
||
5016411 | Hybrid Electrode for AB SCIEX Turbo V and DuoSpray sources 50 µm ID. Requires grounding kit (5016941). Does NOT include Turbo V probe housing (ABSCIEX PN 1017167) |
||
5016874 | Hybrid Electrode for AB SCIEX Turbo V and DuoSpray sources 25 µm ID. Requires grounding kit (5016941). Does NOT include Turbo V probe housing (ABSCIEX PN 1017167) |
||
5016941 | Grounding kit for hybrid electrodes for AB SCIEX Turbo V source | ||
5015996 | Clamp and Rod column heater mounting assembly for AB SCIEX Turbo V and DuoSpray sources. | ||
801-00040 | ABSCIEX ionization probe; 200 μm ID ESI electrode with 30 μm ID fused silica capillary for TurboV source (PN 400-00360) and MS trigger cable (PN 700-00050) |
||
800-00342 | Complete probe for ABSCIEX Turbo V source; includes spare electrode (65 µm) | ||
400-00360 | ABSCIEX ionization probe; 200 μm ID ESI electrode with 30 μm ID fused silica capillary for TurboV source | ||
801-00094 | 200 μm ID ESI electrode w/30 μm ID fused silica capillary for TurboV source | ||
800-00420 | Electrode for ABSCIEX Turbo V source (65 µm) | ||
800-00455 | Electrode for ABSCIEX API 2000 source (65 µm) | ||
801-00095 | Plumbing kit for 200 μm ID ESI electrode for TurboV source; includes 30 μm ID fused silica capillary | ||
801-00028 | Thermo Electron MS interface kit for Xcalibur 1.x | ||
801-00054 | Thermo Electron MS interface kit for Xcalibur 2.x | ||
801-00026 | Plumbing kit for interfacing to Thermo Electron or Bruker Daltonics MS | ||
801-00042 | Bruker Daltonics MS interface kit | ||
accessories and consumables – expressHT, ExpressLC-Ultra and Ekspert MicroLC 200 | |||
part number | description | ||
920-00091 | ExpressHT-Ultra PM Kit | ||
200-00326 | Rotor seal, Express Ultra 6-port | ||
800-00393 | Column oven clamp for ABSCIEX MS probe for ExpressHT-Ultra | ||
700-00050 | Interface cable, ExpressHT to CTC | ||
800-00326 | CTC cooled stack adapter kit, ExpressHT | ||
801-00039 | obsolete; replaced with 801-00095 | ||
910-00101 | 10pk of Fitting, Filled, PEEK, M4 Threads | ||
200-00418 | 1/32″ PEEK one piece fitting | ||
200-00002 | MicroTight Union, PEEK | ||
200-00021 | Mixing tee ferrule for 0.025″ OD tubing | ||
200-00044 | Plug, MicroTight, PEEK, black | ||
200-00138 | Mixing tee ferrule for 365 μm OD capillary, 1/pkg | ||
200-00165 | Fitting, NanoTight, 1/16″, PEEK, 0.90″ long, with Tefzel | ||
200-00254 | Fitting, flanged, 1/16″ | ||
525-00013 | Tee, syringe, Kel-F, for sampling module | ||
910-00020 | Fitting, FingerTight 1/16″, PEEK, 10/pkg | ||
910-00021 | Fitting, hex, 1/16″, SS, 10/pkg (200-00017) | ||
910-00022 | Fitting, MicroTight, 0.025″, PEEK, 10/pkg | ||
910-00023 | Ferrule, 1/16″, PEEK, 10/pkg | ||
910-00024 | Sleeve, PEEK, orange, 405 μm ID, 1/16″ OD, 10/pkg (200-00009) | ||
910-00025 | Sleeve, PEEK, green, 395 μm ID, 0.025″ OD, 10/pkg (200-00014) | ||
910-00026 | Ferrule, 1/16″, SS, 10/pkg (200-00018) | ||
910-00039 | Nanoferrule, injection valve, 10/pkg (200-00090) | ||
910-00040 | Clamp and bolt, injection valve | ||
910-00100 | 0.025″ OD sleeve for 180µm OD tubing (910-00043; 10/pkg) | ||
910-00054 | Sleeve, PEEK, blue, 0.034″ ID, 1/16″ OD, 10/pkg | ||
910-00057 | Ferrule, MicroTight, for 1/32″ OD tubing, 5/pkg | ||
910-00058 | Sleeve, PEEK, tan, 380 μm ID, 1/32″ OD, 10/pkg | ||
910-00060 | Sleeve, PEEK, yellow 180 μm ID, 1/16″ OD, 10/pkg | ||
910-00069 | Ferrule, Tefzel flangeless w/ ss ring, 5/pkg (200-00087) | ||
910-00071 | Fitting, NanoTight, 1/16″, PEEK, short hex nut, 5/pkg (200-00255) | ||
920-00002 | Ferrule, MicroTight, for 0.025″ OD tubing, 10/pkg | ||
920-00003 | Nut, female, MicroTight, 10/pkg | ||
920-00004 | Hex fitting, 1/16″, SS, 3/4″ long, 10/pkg | ||
920-00005 | Hex nut, 1/16″, PEEK, 3/4″ long, 10/pkg | ||
920-00008 | Sleeve, FEP, green, 395 μm ID, 1/16″ OD, 10/pkg | ||
200-00342 | Fitting, UHP PEEK, 6-32 | ||
200-00346 | Fitting, UHP PEEK, M4 (ExpressHT injection valve) | ||
200-00356 | Wrench, Nut Extender Tool (6-32) | ||
200-00374 | Wrench, Nut Extender Tool for Valve Fittings (M4) | ||
200-00404 | Wrench, Nut Extender Tool (6-32 headless) | ||
200-00416 | Adapter, 6-32 to 10-32 fitting, 1/32 to 1/16″ tube | ||
200-00415 | Union, 6-32 fitting,1/32″ tubing UHP | ||
910-00090 | 1/8 ” Super Flangeless nut 10/pkg | ||
910-00091 | 1/8 ” Super Flangeless ferule10/pkg | ||
910-00085 | 1/32″ nut (long) 10/pkg | ||
910-00086 | 1/32″ nut (short) 10/pkg | ||
910-00087 | 1/32″ ferule 10/pkg | ||
200-00098 | Filter Assembly MiniMicro | ||
200-00099 | Filter, MiniMicro, 1 µm | ||
200-00166 | Filter holder, external solvent, with 5 elements, 1 μm, for 360 μm capillary | ||
200-00186 | Filter element, external solvent, 1 μm SS mesh, for 360 μm capillary, blue, 1/pkg | ||
200-00225 | Filter holder, sample, with 5 elements, 1 μm SS mesh, for 1/32″ tubing | ||
300-00020 | Sample vials, 2 ml, septa and caps, box of 100 | ||
910-00076 | PEEK liner for injection port, 10/pkg (525-00017) | ||
800-00123 | HPLC test mixture, 2 ml | ||
800-00159 | Injection port with sapphire guide, Teflon liner, includes needle seal | ||
910-00037 | Ferrule for injection port, 2/pkg | ||
800-00209 | Sample vials, 2 ml, split septa and caps, box of 100 | ||
800-00219 | Injection port with sapphire guide, PEEK liner, includes needle seal | ||
801-00002 | Flow rate calibration kit with 20 μl calibration pipettes (10) for 1 – 30 μl/min flow rate | ||
801-00018 | Consumables kit for ExpressLC-100 | ||
801-00020 | Replacement calibration pipettes, 20 μl, for 1 – 30 μl/min flow rate, 10/pkg | ||
910-00035 | Filter holder, sample injection port, old style, with 5 filter elements, 2mm SS mesh | ||
910-00056 | Filter element, sample, 1 μm SS mesh, for 1/32″ OD tubing, tan, 5/pkg | ||
205-00038 | 50 μm ID /1/32″ OD x 15 cm PEEKSil tubing (natural) | ||
205-00039 | 50 μm ID /1/32″ OD x 20 cm PEEKSil tubing (natural) | ||
205-00040 | 50 μm ID /1/32″ OD x 30 cm PEEKSil tubing (natural) | ||
205-00041 | 50 μm ID /1/32″ OD x 50 cm PEEKSil tubing (natural) | ||
205-00058 | 75 µm ID / 1/32″ OD x 50 cm PEEKSil tubing (black) | ||
205-00061 | 75 µm ID / 1/32″ OD x 30 cm PEEKSil tubing (black) | ||
200-00329 | Mobile Phase filter | ||
200-00040 | Nut, Fingertight, PEEK | ||
801-00088 | Tube, 1/32″ od, 175 μm id, 65 mm (PEEK) | ||
801-00089 | Tube, 1/32″ od, 175 μm id, 45 mm (PEEK) | ||
400-00467 | FUSE UL MED.ACT 5X20MM 3A CART | ||
700-00050 | Interface cable, ExpressHT to CTC | ||
801-00074 | Solvent bottle, 500 ml with gray cap | ||
801-00075 | Solvent bottle, 1L with gray cap | ||
801-00079 | Calibration Kit, EX100 HT-Ultra | ||
200-00357 | Wash pump check valve, inlet, Non-Metal, .06″ Thru | ||
200-00358 | Wash pump check valve, outlet, Non-Metal, .06″ Thru | ||
620-00159 | Needle Seal (Tube & Ferrule) | ||
200-00360 | 75 µm ID / 1/32″ OD x 10 cm PEEKSil tubing (black) | ||
205-00071 | 75 µm ID / 1/32″ OD x 20 cm PEEKSil tubing (black) | ||
205-00069 | 50 µm ID / 1/32″ OD x 10 cm PEEKSil tubing | ||
205-00089 | 25 µm ID / 1/32″ OD x 5 cm PEEKSil tubing | ||
205-00043 | 100 μm ID /1/32″ OD x 20 cm PEEKSil tubing (red) | ||
200-00447 | injection port, PEEK, 10-32 | ||
200-00364 | bulkhead reducing union, 1/16 to 1/32in | ||
accessories and consumables – ExpressRT sampling module | |||
part number | description | ||
200-00253 | Plug, 1/14-28, PFA, for ExpressRT sampling module | ||
200-00260 | Nut, sampling probe retaining, for ExpressRT sampling module | ||
910-00070 | Fitting, low pressure, 1/16″, white, for ExpressRT sampling module, 5/pkg (200-00252) | ||
910-00073 | Frit-in-a-ferrule, sampling probe, for ExpressRT sampling module, 5/pkg (200-000259) | ||
910-00075 | Fitting, sample probe, 1/4″-28, Tefzel, for ExpressRT sampling module, 10/pkg (200-00283) | ||
801-00077 | accesory kit for sampling module | ||
200-00230 | Syringe, 250 μl, for ExpressRT sampling module | ||
525-00024 | Tubing, transfer, for ExpressRT sampling module | ||
801-00049 | Probe, sampling, for ExpressRT sampling module | ||
801-00086 | Metal-free probe for ExpressRT sampling module | ||
910-00074 | Filtering screen, sample probe, SS, for ExpressRT sampling module, 20/pkg (525-00023) | ||
910-00078 | Filtering screen, sample probe, fiber, for ExpressRT sampling module, 20/pkg (525-00026) | ||
accessories and consumables – ExpressLC-100 and -800 | |||
part number | description | ||
801-00004 | accessory kit ExpressLC | ||
200-00098 | Filter Assembly MiniMicro | ||
200-00099 | Filter, MiniMicro, 1µm | ||
200-00166 | Filter holder, external solvent, with 5 elements, 1 μm, for 360 μm capillary | ||
200-00186 | Filter element, external solvent, 1 μm SS mesh, for 360 μm capillary, blue, 1/pkg | ||
200-00225 | Filter holder, sample, with 5 elements, 1 μm SS mesh, for 1/32″ tubing | ||
300-00020 | Sample vials, 2 ml, septa and caps, box of 100 | ||
910-00076 | PEEK liner for injection port, 10/pkg (525-00017) | ||
800-00123 | HPLC test mixture, 2 ml | ||
800-00159 | Injection port with sapphire guide, Teflon liner, includes needle seal | ||
910-00037 | Ferrule for injection port, 2/pkg | ||
800-00209 | Sample vials, 2 ml, split septa and caps, box of 100 | ||
800-00219 | Injection port with sapphire guide, PEEK liner, includes needle seal | ||
801-00002 | Flow rate calibration kit with 20 μl calibration pipettes (10) for 1 – 30 μl/min flow rate | ||
801-00018 | Consumables kit for ExpressLC-100 | ||
801-00020 | Replacement calibration pipettes, 20 μl, for 1 – 30 μl/min flow rate, 10/pkg | ||
910-00035 | Filter holder, sample injection port, old style, with 5 filter elements, 2mm SS mesh | ||
910-00056 | Filter element, sample, 1 μm SS mesh, for 1/32″ OD tubing, tan, 5/pkg | ||
910-00068 | Replacement capillaries kit for ExpressLC-100. Includes all SS and fused silica capillaries used inside an ExpressLC-100, with necessary fittings. |
||
910-00065 | Replacement capillaries kit for ExpressLC-100. Includes all SS capillaries used inside an ExpressLC-100, with necessary fittings. | ||
801-00012 | Capillary kit, ExpressLC-100 | ||
801-00013 | Capillary kit, ExpressLC-800, for all 8 channels | ||
801-00019 | Capillary kit, ExpressLC-800, for one channel only | ||
910-00028 | Sample loop, PEEKSil, 235 nl, 12 cm, 360 μm OD, 50 μm ID, 1/pkg (205-00016) | ||
910-00029 | Capillary, injection valve-to-column, PEEKSil, 11 cm, 360 μm, OD, 30 μm ID, 2/pkg (205-00017) | ||
910-00030 | Chip based filter (between autosampler and cHiPLC nanoflex or column and detector) | ||
910-00031 | Capillary, mixing tee-to-injector, PEEKSil, 8 cm, 360 μm OD, 50 μm ID, 2/pkg (205-00015) | ||
910-00033 | Capillary, injection valve-to-waste vial, fused silica, 15 cm, 360 μm OD, 100 μm ID, 2/pkg (205-00023) | ||
910-00034 | Capillary, ExpressLC-100 flow cell-to-waste vial, fused silica, 20 cm, 360 μm OD, 100 μm ID, 2/pkg (205-00036) | ||
910-00036 | Capillary, ExpressLC-800 flow cell to waste vial, fused silica, 35 cm, 360 μm OD, 100 μm ID, 2/pkg (205-00035) | ||
910-00055 | Capillary, injection port-to-injection filter, PEEKSil, 5cm, 1/32″ OD, 100 μm ID, 2/pkg (205-00018) | ||
910-00059 | Capillary, sample filter-to-injection valve, fused silica, 13 cm, 360 μm OD, 75 μm ID, 2/pkg (205-00031) |