备件
| P/N: | Product Description |
| 200400.001 | Replacement 5 mm diameter Light Guide for ARES and AR UV-Curingand Photo-Curing Options |
| 200974.001 | SER2 Standard Drum Pair Set for ARES Rheometers |
| 200974.003 | SER3 Standard Drum Pair Set for ARES-G2/ARES Rheometers |
| 200975.001 | SER2 Knurled Surface Drum Pair Set for ARES Rheometers |
| 200975.003 | SER3 Knurled Surface Drum Pair Set for ARES-G2/ARES Rheometers |
| 200976.001 | SER2 Rough Surface Drum Pair Set for ARES Rheometers |
| 200976.003 | SER3 Rough Surface Drum Pair Set for ARES-G2/ARES Rheometers |
| 200977.001 | SER2 Securing Clamps for ARES Rheometers (pkg. of 6) |
| 200977.002 | Securing Clamps for DHR & AR SER3/2 and ARES-G2 SER3 (pkg. of 6) |
| 200978.001 | SER3 and SER2 Dual Blade Cutter Assembly |
| 200979.001 | Razor Blades for SER3 and SER2 Dual Blade Cutter Assembly (pkg. of 50) |
| 203330.001 | Keysight E4980AL-102 LCR MeterNote: For ARES-G2, RSA-G2, and DHR DETA: frequency range: 20 Hz to 1 MHz;AC test signal (potential) 0.001 to 2 Volts (115/230V; 50/60 Hz). |
| 203599.901 | Universal AC adapter kit for DSL Router |
| 251471.002 | DSL Router with 4-Port SwitchNote: For communication between an external controller and Thermal and Rheology instruments. |
| 400.02589 | Steel Reference Standard |
| 401014.901 | ARES-G2 Smart Swap Peltier PlateNote: Requires Environmental Control Box (P/N: 401949.901) andappropriate Peltier Circulator. |
| 401035.901 | ARES FCO Advanced Melt Rheology Add-On Geometry Bundle(Designed for use with Melt Rheology Geometry Bundle) includes:- Stainless Steel 50 mm Parallel Plates (two of P/N: 401968.901);- Stainless Steel 25 mm Serrated Plates (two of P/N: 401.00512.1);- Stainless Steel 50 mm 0.04 rad Cone (P/N: 401963.901)Note: Compatible with ARES Classic Instruments. |
| 401041.901 | ARES-G2, RSA-G2 and DMA 3200 FCO LN2 Controller Option |
| 401070.901 | Heat Shield for ARES-G2 Forced Convection Oven |
| 401177.901 | ARES-G2 UV-Curing Option without Light Source |
| 401177.902 | ARES-G2 UV-Curing Option with Light Source |
| 401647.901 | ARES, Stainless Steel, Cross Hatched, 8 mm Parallel Plate |
| 401667.901 | ARES, Stainless Steel, Cross Hatched, 25 mm Parallel Plate |
| 401687.901 | ARES, Stainless Steel, Cross Hatched, 50 mm Parallel Plate |
| 401711.901 | ARES-G2 and RSA-G2 FCO Camera |
| 401798.901 | ARES/RSA3 to ARES-G2/RSA-G2 LN2 Upgrade Kit |
| 401827.901 | ARES Stainless Steel Helical Rotor |
| 401892.901 | ARES-G2 and RSA-G2 Forced Convection Oven (FCO) |
| 401940.901 | ARES Electro-Rheological Analysis Accessory for ARES-G2 (110VAC) |
| 401940.902 | ARES Electro-Rheological Analysis Accessory for ARES-G2 (220VAC) |
| 401949.901 | ARES-G2 Environmental Control BoxNote: Required for Peltier Plate Temperature Control. |
| 401962.901 | ARES, Titanium, 50 mm 0.04 rad Cone (2.29 deg) |
| 401963.901 | ARES, Stainless Steel, 50 mm 0.04 rad Cone (2.29 deg) |
| 401964.901 | ARES, Titanium, 50 mm 0.02 rad Cone (1.15 deg) |
| 401965.901 | ARES, Stainless Steel, 50 mm 0.02 rad Cone (1.15 deg) |
| 401968.901 | ARES, Stainless Steel, 50 mm Parallel Plate |
| 401972.901 | ARES, Titanium, 25 mm 0.02 rad Cone (1.15 deg) |
| 401973.901 | ARES, Titanium, 25 mm 0.1 rad Cone (5.73 deg) |
| 401975.901 | ARES, Titanium, 25 mm 0.04 rad Cone (2.29 deg) |
| 401976.901 | ARES, Stainless Steel, 25 mm 0.04 rad Cone (2.29 deg) |
| 401977.901 | ARES, Stainless Steel, 25 mm 0.02 rad Cone (1.15 deg) |
| 401978.901 | ARES, Stainless Steel, Serrated, 25 mm Parallel Plate |
| 401981.901 | ARES, Stainless Steel, 25 mm Parallel Plate |
| 401985.901 | ARES, Stainless Steel, 8 mm Parallel Plate |
| 401995.901 | ARES, Sealed Bath Recessed End CouetteNote: Includes the following:- 32 mm diameter Titanium Bob with Recessed End;- 34 mm diameter Stainless Steel Cup |
| 401996.901 | ARES, Sealed Bath Small Volume Recessed End CouetteNote: Includes the following:- 16.5 mm diameter Titanium Bob; – 17 mm diameter Stainless Steel Cup |
| 401997.901 | ARES, Sealed Bath Double Wall CouetteNote: Includes the following:- 34 mm OD/27.95 mm ID Stainless Steel Cup;- 32 mm OD/29.5 mm ID Titanium Bob |
| 402280.901 | ARES Peltier Plate Solvent Trap AccessoryNote 1: Requires use of solvent trap geometries.Note 2: For use with ARES Classic and ARES-G2 Smart Swap Peltier Plates ONLY. |
| 402302.901 | ARES, Stainless Steel, 40 mm Parallel Plate |
| 402303.901 | ARES, Stainless Steel, Disposable Plate FixtureNote: Requires disposable plates. |
| 402305.901 | ARES, Stainless Steel, 8 mm 0.1 rad Cone (5.73 deg) |
| 402309.901 | ARES, Titanium, 25 mm Parallel Plate |
| 402310.901 | ARES, Titanium, 50 mm Parallel Plate |
| 402311.901 | ARES, PPS, 25 mm Upper Plate; Maximum Temperature = 150 °C |
| 402312.901 | ARES, PPS, 40 mm Upper Plate; Maximum Temperature = 150 °C |
| 402313.901 | ARES, PPS, 50 mm Upper Plate; Maximum Temperature = 150 °C |
| 402314.901 | ARES, PPS, 25 mm 0.1 rad Cone; Maximum Temperature = 150 °C |
| 402315.901 | ARES, PPS, 50 mm 0.04 rad Cone; Maximum Temperature = 150 °C |
| 402317.901 | ARES, Stainless Steel, 25 mm 0.1 rad Cone (5.73 deg) |
| 402319.901 | ARES FCO Melt Rheology Geometry BundleThis bundle includes the following:- Torsion Rectangular Fixture (P/N: 403220.901) Stainless Steel;- 25 mm parallel plates (two of P/N: 401981.901) Stainless Steel;- 25 mm 0.1 rad Cone (P/N: 402317.901)Note: Compatible with ARES Classic Instruments. |
| 402323.901 | ARES FCO Thermoset Testing Geometry BundleThis bundle includes the following:- Torsion Rectangular Fixture (P/N: 403220.901);- Disposable Plate Fixture (two of P/N: 402303.901);- One Pair 8 mm Aluminum Disposable Plates;- One Pair 25 mm Aluminum Disposable PlatesNote: Compatible with ARES Classic Instruments. |
| 402328.901 | ARES, Sealed Bath Fluid Rheology Geometry BundleNote: For ARES-G2 and ARES Classic Rheometers.This bundle includes:- 50 mm Titanium Upper Plate and Stainless Lower Parallel Plate;- Titanium Upper 50 mm 0.04 rad Cone;- Recessed End Couette with 34 mm diameter Cup; – 32 mm diameter Bob |
| 402330.901 | ARES, Sealed Bath Advanced Fluids Rheology Geometry BundleNote: For ARES-G2 and ARES Classic Rheometers.This bundle includes:- 25 mm diameter Titanium Upper Plate and Stainless Lower Parallel Plate;- Titanium 25 mm diameter 0.04 rad Cone;- Small volume recessed end Couette with 17 mm diameter Stainless Steel Cup;- 16.5 mm diameter Titanium Bob |
| 402331.901 | ARES-G2 Melt Sample Preparation Kit; includes:This kit includes the following:- 8 mm, 25 mm punch and die set (to 3 mm thick);- Aluminum scraping tool for trimming sample;- Brass brush for cleaning plates;- Precision knife for sample trimming;- Polymer Pellet Melt Ring for 25 mm diameter, Upper Cones and PlatesNote: Compatible with ARES Classic Instruments. |
| 402333.901 | ARES Recessed End Ambient CouetteThis includes the following:- 25 mm diameter Titanium Bob;- 27 mm diameter Stainless Steel Cup and PRTNote: For ARES-G2 and ARES Classic Rheometers. |
| 402500.901 | ARES-G2, APS, Jacket |
| 402515.901 | ARES-G2, APS, Split Solvent Trap Cover for Cones and Parallel Plates |
| 402551.901 | ARES-G2 and RSA-G2 DETA Accessory Kit (LCR Meter NOT included):Note: Requires two ARES 25 mm DETA Geometries (P/N: 402553.901) andKeysight E4980A LCR Meter (P/N: 613.04946), orKeysight E4980AL LCR Meter (P/N: 203330.001). |
| 402553.901 | ARES 25 mm DETA GeometryNote: For use with the ARES DETA option (P/N: 402551.901). |
| 402560.901 | ARES-G2 Torsion Cylindrical Clamp SetNote: Sample holder diameters: 1.5, 3, and 4.5 mm. |
| 402611.901 | DHR, ARES-G2, APS, Aluminum, 8 mm, Quick Change Disposable Plate(pkg. of 20) |
| 402612.901 | DHR, ARES-G2, APS, Aluminum, 20 mm, Quick Change Disposable Plate(pkg. of 20) |
| 402613.901 | DHR, ARES-G2, APS, Aluminum, 25 mm, Quick Change Disposable Plate(pkg. of 20) |
| 402619.901 | ARES-G2, APS, Standard Flat Plate |
| 402620.901 | ARES-G2, APS, Hard Anodized Aluminum, 30 mm Dia., Cup |
| 402621.901 | ARES-G2, APS, Stainless Steel, 27.7 mm Dia., DIN Bob |
| 402622.901 | DHR, ARES-G2, APS, Stainless Steel, 50 mm, Quick Change Plate |
| 402623.901 | DHR, ARES-G2, APS, Stainless Steel, 40 mm, Quick Change Plate |
| 402624.901 | DHR, ARES-G2, APS, Stainless Steel, 25 mm, Quick Change Plate |
| 402625.901 | DHR, ARES-G2, APS, Stainless Steel, 8 mm, Quick Change Plate |
| 402627.901 | DHR, ARES-G2, APS, Stainless Steel, Cross Hatched, 8 mm,Quick Change Plate |
| 402628.901 | DHR, ARES-G2, APS, Stainless Steel, Cross Hatched, 25 mm,Quick Change Plate |
| 402629.901 | DHR, ARES-G2, APS, Stainless Steel, Cross Hatched, 40 mm,Quick Change Plate |
| 402630.901 | DHR, ARES-G2, APS, Hard Anodized Aluminum, 25 mm,Quick Change Plate |
| 402631.901 | DHR, ARES-G2, APS, Hard Anodized Aluminum, 40 mm,Quick Change Plate |
| 402632.901 | DHR, ARES-G2, APS, Hard Anodized Aluminum, 50 mm,Quick Change Plate |
| 402633.901 | DHR, ARES-G2, APS, Titanium, 25 mm, Quick Change Plate |
| 402634.901 | DHR, ARES-G2, APS, Titanium, 50 mm, Quick Change Plate |
| 402641.901 | ARES-G2, APS, Hard Anodized Aluminum, 34 mm Dia., Cup |
| 402673.901 | ARES-G2, APS, Stainless Steel, 27.7 mm Dia., 41.5 mm Height, Recessed End Bob |
| 402674.901 | ARES-G2, APS, Titanium, 31.4 mm Dia., 47.1 mm Height, Recessed EndBob |
| 402675.901 | ARES-G2, APS, Stainless Steel, 27.7 mm Dia., 41.5 mm Height, Vane Bob |
| 402676.901 | ARES-G2, APS, Titanium, Double Gap Bob:Inner Dia. = 29.4 mm, Outer Dia. = 32 mm, Height = 48 mm,Sample Volume = 9.4 mL |
| 402676.902 | ARES-G2, APS, Titanium, Narrow Gap Double Gap Bob:Inner Dia. = 28.6 mm, Outer Dia. = 33 mm, Height = 49.5 mm,Sample Volume = 5.0 mL |
| 402677.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, 40 mm, Parallel Plate |
| 402677.902 | ARES, Stainless Steel, Heat Break, Solvent Trap, 50 mm, Parallel Plate |
| 402677.903 | ARES, Stainless Steel, Heat Break, Solvent Trap, 25 mm, Parallel Plate |
| 402678.901 | ARES-G2, APS, Hard Anodized Aluminum, 20 mm Dia., Cup |
| 402679.901 | ARES-G2, APS, Stainless Steel, 18.6 mm Dia., 27.9 mm Height, Conical EndDIN Bob |
| 402680.901 | ARES-G2, APS, Stainless Steel, 18.6 mm Dia., 27.9 mm Height,Recessed End Bob |
| 402681.901 | DHR, ARES-G2, APS, Hard Anodized Aluminum, 42 mm Dia.,15 mm Edge Height, Immersion CupNote: Includes the following:Two removable sidewalls (one aluminum and one clear polycarbonate) for easy sample loading and trimming. |
| 402682.901 | ARES-G2, APS, Stainless Steel, 15 mm Dia., 38 mm Height, Wide Gap VaneBob |
| 402683.901 | ARES, PPS, Heat Break, Solvent Trap, 40 mm, Parallel Plate |
| 402683.902 | ARES, PPS, Heat Break, Solvent Trap, 50 mm, Parallel Plate |
| 402683.903 | ARES, PPS, Heat Break, Solvent Trap, 25 mm, Parallel Plate |
| 402684.901 | ARES-G2, APS, Hard Anodized Aluminum, 34 mm Dia., Double Gap Cup |
| 402684.902 | ARES-G2, APS, Stainless Steel, 34 mm Dia., Double Gap Cup |
| 402691.901 | ARES-G2, APS, Solvent Trap Cover for Concentric Cylinders |
| 402735.901 | ARES-G2 Draft Shield |
| 402739.901 | Aluminum, 25 mm Disposable Plates with Drip Channel (pkg. of 20) |
| 402741.901 | ARES-G2, APS, Stainless Steel, 30 mm Dia., Cup (with embedded PRT) |
| 402751.901 | DHR, ARES-G2, APS, Quick Change Disposable Plate Holder |
| 402751.902 | DHR, ARES-G2, APS, Quick Change Plate Holder |
| 402752.901 | ARES-G2, Electro-Rheology, Stainless Steel, 50 mm, Upper PlateNote: For upper use only and NOT compatible with the FCO. |
| 402754.901 | ARES-G2, Electro-Rheology, Stainless Steel, 25 mm, Upper PlateNote: For upper use only and NOT compatible with the FCO. |
| 402760.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, 40 mm, 2 deg Cone |
| 402760.903 | ARES, Stainless Steel, Heat Break, Solvent Trap, 40 mm, 1 deg Cone |
| 402761.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, 25 mm, 1 deg Cone |
| 402762.901 | ARES, PPS, Heat Break, Solvent Trap, 25 mm, 1 deg Cone |
| 402763.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, 50 mm, 2 deg Cone |
| 402763.903 | ARES, Stainless Steel, Heat Break, Solvent Trap, 50 mm, 1 deg Cone |
| 402764.901 | ARES, PPS, Heat Break, Solvent Trap, 40 mm, 2 deg Cone |
| 402764.903 | ARES, PPS, Heat Break, Solvent Trap, 40 mm, 1 deg Cone |
| 402765.901 | ARES, PPS, Heat Break, Solvent Trap, 50 mm, 2 deg Cone |
| 402765.903 | ARES, PPS, Heat Break, Solvent Trap, 50 mm, 1 deg Cone |
| 402766.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, Cross Hatched, 40 mm,Parallel Plate |
| 402766.902 | ARES, Stainless Steel, Heat Break, Solvent Trap, Cross Hatched, 25 mm,Parallel Plate |
| 402766.903 | ARES, Stainless Steel, Heat Break, Solvent Trap, Cross Hatched, 50 mm,Parallel Plate |
| 402767.901 | ARES, Stainless Steel, Heat Break, Solvent Trap, Sandblasted, 40 mm,Parallel Plate |
| 402767.902 | ARES, Stainless Steel, Heat Break, Solvent Trap, Sandblasted, 50 mm,Parallel Plate |
| 402767.903 | ARES, Stainless Steel, Heat Break, Solvent Trap, Sandblasted, 25 mm,Parallel Plate |
| 402768.901 | ARES-G2, APS, Stainless Steel, Sandblasted, 50 mm,Quick Change Plate |
| 402769.901 | DHR, ARES-G2, APS, Stainless Steel, Sandblasted, 40 mm,Quick Change Plate |
| 402770.901 | DHR, ARES-G2, APS, Stainless Steel, Sandblasted, 25 mm,Quick Change Plate |
| 402782.901 | ARES-G2, APS, HA AL, 34 mm Dia., OSP Slotted Double Gap Cup |
| 402796.901 | ARES-G2, APS, Titanium, OSP Slotted Double Gap Bob |
| 402796.902 | ARES-G2, APS, Titanium, OSP Slotted Narrow Gap Double Bob |
| 402800.901 | ARES-G2, Cone Partitioned Plate Geometry for FCO |
| 402811.901 | DHR, ARES-G2, APS, Stainless Steel, Sandblasted, 8 mm,Quick Change Plate |
| 402817.901 | Vane rotor for DHR & ARES-G2 High Sensitivity Pressure Cell (HSPC)Note: Requires DHR (P/N: 547050.901) or ARES-G2 (P/N: 402818.901) High Sensitivity Pressure Cell. |
| 402818.901 | ARES-G2 High Sensitivity Pressure CellNote: Requires Advanced Peltier System (P/N: 402500.901). |
| 402820.901 | ARES-G2, Double Wall Ring Interfacial (DWR) Rheology System:Note: Includes DWR Pt/Ir Ring Geometry and Delrin Trough, which mounts onthe APS Flat Plate.Requires APS Flat Plate (P/N: 402619.901) and APS Jacket(P/N: 402500.901). |
| 402825.901 | ARES-G2, Double Wall Ring, Pt-Ir |
| 403056.901 | DHR, ARES-G2 Replacement Clamps for EVA (pkg. of 6) |
| 403064.901 | Acrylic, 20 mm diameter, Disposable Parallel Plates for ARES UV-Option(pkg. of 10)Note: For use with the upper plate fixture of ARES-UV option and thelower plate fixture of DHR/AR-UV option. |
| 403065.901 | Aluminum, 20 mm diameter, Disposable Parallel Plates for ARES UV-Option(pkg. of 10)Note: For use with the lower plate fixture of ARES-UV option andPhoto-Curing Option upper quartz plate and fixture. |
| 403074.901 | ARES EVF, Replacement Drum Pins, One Set |
| 403076.901 | ARES EVF, Sample Mold and Plates |
| 403090.001 | SER3 Universal Testing Platform for ARES/ARES-G2 |
| 403153.001 | Quartz, 20 mm diameter, Parallel Plate for ARES and DHR/AR UV-CuringOptionNote: For use with the upper plate fixture of ARES-UV option and thelower plate fixture of DHR/AR-UV option. |
| 403165.901 | ARES EVF, Extensional Viscosity FixtureNote: ARES Classic requires 2KFRT transducer. |
| 403170.001 | Replacement Remote Radiometer/Dosimeter for ARES UV-Curing Option |
| 403171.002 | Stainless Steel, 20 mm diameter, Parallel Plate for ARES UV-OptionNote: For use with the lower plate fixture of ARES-UV option and Photo-Curing Option upper quartz plate and fixture. |
| 403209.901 | Air Cooled Peltier Circulator (110/220VAC; 50/60Hz)Note: For DHR & AR and ARES Rheometers. |
| 403220.901 | ARES-G2 Torsion Rectangular Clamp Set |
| 403220.902 | ARES Classic Torsion Rectangular Clamp Set (Ver 1 through 8) |
| 404000.901 | ARES-G2, Disposable DETA GeometryNote: For use with the ARES DETA option (P/N: 402551.901). |
| 404008.901 | Motor Boost Accessory for ARES-G2 |
| 404041.901 | ARES-G2, RSA-G2 & DMA 3200 FCO Air Chiller PanelNote: For use with ACS-2 and ACS-3 Air Chiller Systems. |
| 404131.901 | ARES-G2 Extensional Viscosity Accessory (EVA) |
| 404140.902 | ARES-G2 Standard Drum Pair Set for EVA |
| 404140.904 | ARES-G2 Knurled Surface Drum Pair Set for EVA |
| 404140.906 | ARES-G2 Roughened Surface Drum Pair Set for EVA |
| 404500.901 | Peltier Circulator TCube Edge Model 5A (110/220VAC; 50/60Hz) withfittings for rheometersNote: For use with ARES-G2 Peltier Plate and Peltier Concentric CylinderSystems. |
| 405000.901 | ACS-3 Air Chiller System (240VAC/60Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel (P/N: 404041.901) for operation. |
| 405000.902 | ACS-3 Air Chiller System (220-230VAC/50Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel (P/N: 404041.901) for operation. |
| 405001.901 | ACS-2 Air Chiller System (240VAC/60Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel (P/N: 404041.901) for operation. |
| 405001.902 | ACS-2 Air Chiller System (220-230VAC/50Hz)Note: Requires ARES-G2 & RSA-G2 FCO Air Chiller Panel (P/N: 404041.901) for operation. |
| 523400.907 | Aluminum, 40 mm Disposable Plate |
| 532069.901 | ARES-G2, 3-Point Bending Geometry |
| 532070.901 | ARES-G2, Cantilever Bending Geometry |
| 532078.901 | ARES-G2, Tribo-Rheometry Coupling Adapter, Long |
| 532078.902 | ARES-G2, Tribo-Rheometry Coupling Adapter, Short |
| 532079.901 | ARES-G2, FCO, Tribo-Rheometry Lower Geometry Holder |
| 532080.901 | DHR, ARES-G2, APS, Tribo-Rheometry Lower Geometry Holder |
| 533242.901 | Tribo-Rheometry Accessory Base Kit |
| 533249.901 | Tribo-Rheometry, 5/16” Truncated SST Balls (pkg. of 12) |
| 533250.901 | Tribo-Rheometry, 1/2” SST Balls (pkg. of 25) |
| 533273.901 | Tribo-Rheometry, Single Ball Upper Geometry Holder, Medium |
| 533273.902 | Tribo-Rheometry, Single Ball Upper Geometry Holder, Short |
| 533273.903 | Tribo-Rheometry, Single Ball Upper Geometry Holder, Long |
| 533274.901 | Tribo-Rheometry, Ball on 3 Balls Lower Geometry |
| 533281.901 | Tribo-Rheometry, SST Cup 45 mm Lower Geometry |
| 533282.901 | Tribo-Rheometry, 3 Plates Lower Geometry |
| 533283.901 | Tribo-Rheometry, Ring on Plate Upper Geometry Holder |
| 533284.901 | Tribo-Rheometry, Ring Upper Geometry (pkg. of 3) |
| 533290.901 | Tribo-Rheometry, 3 Balls on Plate Upper Geometry Holder |
| 533291.901 | Tribo-Rheometry, Ball on 3 Plates SST Test Plates (pkg. of 30) |
| 554007.901 | Asphalt Sample Molds, 1 Pair |
| 613.04946 | Keysight E4980A LCR MeterNote: For ARES-G2, RSA-G2, and DHR DETA: frequency range: 20Hz to 2MHz; AC test signal (potential) 0.005 to 20 Volts (115/230VAC; 50/60Hz). |
| 700.01011 | PDMS, 2 oz |
| 700.01016 | Silicone Oil, 1000 cP |
| 700.01294.11 | Serrated Aluminum, 8 mm Disposable Plates (pkg. of 2) |
| 700.01294.17 | Aluminum, 8 mm Disposable Plates (pkg. of 20) |
| 700.01294.3 | Aluminum, 25 mm Disposable Plates (pkg. of 20 |
| 700.01294.4 | Aluminum, 40 mm Disposable Plates (pkg. of 20) |
| 700.01294.5 | Aluminum, 50 mm Disposable Plates (pkg. of 20) |
| 700.01294.6 | Serrated Aluminum, 25 mm Disposable Plates (pkg. of 2) |
| 700.01294.7 | Serrated Aluminum, 50 mm Disposable Plates (pkg. of 2) |
| 700.01295.3 | Stainless Steel, 25 mm Disposable Plates (pkg. of 20) |
| 700.01295.4 | Stainless Steel, 40 mm Disposable Plates (pkg. of 20) |
| 700.01295.5 | Stainless Steel, 50 mm Disposable Plates (pkg. of 20) |
| 700.01295.6 | Serrated Stainless Steel, 25 mm Disposable Plates (pkg. of 2) |
| 700.01295.9 | Stainless Steel, 8 mm Disposable Plates (pkg. of 20) |
| 700.02451.1 | Aluminum, 25 mm 0.1 rad (5.73 deg) Disposable Cone (pkg. of 10) |
| 700.02451.2 | Aluminum, 25 mm 0.02 rad (1.15 deg) Disposable Cone (pkg. of 10) |
| 700.02451.3 | Aluminum, 50 mm 0.04 rad (2.29 deg) Disposable Cone (pkg. of 10) |
| 700.02648 | Disposable Plate Sample Mold, 25 mm |
| 700.02657.2 | ARES, RSA, and TAM Air Dryer |
| 700.02678 | Aluminum, 42 mm Disposable Cup, (1 piece) |
| 700.03464 | ARES, Stainless Steel Double Wall Cup for Sealed Bath |
| 708.01228 | ARES, Stainless Steel 18 mm Vaned BobNote: For use with Sealed Bath configured with lower 34 mm Stainless Steel Cup. |
| 708.01440 | ARES Linear Tack Testing Tool |
| 708.01442 | ARES Optical Parallel Plate for OAMNote: Includes 38.1 mm upper and lower glass parallel plates. |
| 708.01458 | ARES Linear Film/Fiber Testing ToolNote: For use with ARES-G2 and ARES Classic Instruments configured with2KFRTN transducers. |
| 708.01471 | ARES, Stainless Steel, 25 mm Lower Plate for Sealed Bath |
| 708.01472 | ARES, Stainless Steel, 50 mm Lower Plate for Sealed Bath |
| 926018.001 | LAOS and FT RHEOLOGY for TRIOSNote: Large Amplitude Oscillatory Shear and Fourier Transform Rheology Software for TRIOS. |
| 926019.001 | Rheology Polymer Library for TRIOSNote: Includes software for Molecular Weight Distribution Calculations. |
| 935009.001 | Filter, External, 320 – 480 nm(for the Omnicure S-2000 with external filter adapter) |
| 935009.002 | Filter, External, 320 – 390 nm(for the Omnicure S-2000 with external filter adapter) |
| 935009.003 | Filter, External, 365 nm(for the Omnicure S-2000 with external filter adapter) |
| 935009.004 | Filter, External, 400 – 500 nm(for the Omnicure S-2000 with external filter adapter) |
| 935014.901 | PCA/UV External Filter Adapter Accessory KitNote: Allows use of external filters with the PCA (P/N: 935000.901). |
河南东吉高科有限公司